Pico Technology TA044 Active Differential Probe, 100x/1000x, 70MHz, 7000V
$1,075
Model :
- TA044
TA044 Active Differential Probe
Specs:
- DC to 70 MHz
- 1:100/1000 Attenuation ratio
- Accuracy ±2%
- Input Impedance 10 Megohms // 10 pF each side to ground
- CMRR (typical) -80 dB @ 60 Hz; -50 dB @ 1 MHz
- Length of Input Leads 60 cm
- Length of BNC Lead 90 cm
- Dimension (LxWxH) 202 mm x 83 mm x 38 mm
The TA044 is an active differential probe suitable for high common-mode voltage measurement applications up to ±7000 V (DC + peak AC).
This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high-voltage differential measurements. Applications include making safe measurements in power circuit applications and acquisition of low-speed balanced differential signals found in serial communications buses.
Note: The spring hooks supplied with this probe are rated at 1000 V.
Brand: Pico Technology
Bandwidth: 70 MHz
Attenuation: 100X, 1000X
Cable Length: 0.6 m
Type: Differential Probe
Interface: BNC
Input Capacitance: 10 pF
Safety Rating: CAT1
Max Input Voltage: 7000 V
Input Impedance: 10 MΩ
Operating Temperature Range: -10 to 40°C
Lead Length: 0.9 m
Empty
Empty